WEKO3
アイテム
{"_buckets": {"deposit": "6679c54d-afa0-4cd6-a74b-d515682c3647"}, "_deposit": {"created_by": 10, "id": "333", "owners": [10], "pid": {"revision_id": 0, "type": "depid", "value": "333"}, "status": "published"}, "_oai": {"id": "oai:fukuchiyama.repo.nii.ac.jp:00000333", "sets": ["55"]}, "author_link": ["444"], "item_3_biblio_info_12": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2014-03-31", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "2", "bibliographicPageEnd": "82", "bibliographicPageStart": "73", "bibliographicVolumeNumber": "4", "bibliographic_titles": [{"bibliographic_title": "成美大学紀要 "}]}]}, "item_3_description_10": {"attribute_name": "抄録(日)", "attribute_value_mlt": [{"subitem_description": "本論文は、小規模風力発電における発電量向上のための回路方式を実験的に検討した。実験の結果、蓄電素子として電気二重層コンデンサ(EDLC)を用いることにより、従来から用いられている蓄電池を用いた回路に比べ、低風速で発電電力を蓄えることができた。また、MPPT(Max Peak Power Tracking)回路の付加により、同一発電条件での蓄電量を増加させることができた。", "subitem_description_type": "Other"}]}, "item_3_description_15": {"attribute_name": "表示順", "attribute_value_mlt": [{"subitem_description": "5", "subitem_description_type": "Other"}]}, "item_3_source_id_1": {"attribute_name": "雑誌書誌ID", "attribute_value_mlt": [{"subitem_source_identifier": "AA12547156", "subitem_source_identifier_type": "NCID"}]}, "item_3_source_id_19": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "21860300", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "神谷, 達夫"}, {"creatorName": "カミタニ, タツオ", "creatorNameLang": "ja-Kana"}], "nameIdentifiers": [{"nameIdentifier": "444", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2017-07-03"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "seibi42-5.pdf", "filesize": [{"value": "31.2 MB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 31200000.0, "url": {"label": "seibi42-5", "url": "https://fukuchiyama.repo.nii.ac.jp/record/333/files/seibi42-5.pdf"}, "version_id": "48ea0772-0c52-4acb-908e-d8f79c4fa3ce"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "風力発電", "subitem_subject_scheme": "Other"}, {"subitem_subject": "蓄電", "subitem_subject_scheme": "Other"}, {"subitem_subject": "MPPT 回路", "subitem_subject_scheme": "Other"}, {"subitem_subject": "電気二重層コンデンサ", "subitem_subject_scheme": "Other"}, {"subitem_subject": "wind power generation", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "charge control", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Max Peak Power Tracking circuit", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "electric double -layer capacitor", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "低風速に対応する風力発電用蓄電装置の検討", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "低風速に対応する風力発電用蓄電装置の検討"}, {"subitem_title": "The Review of the Charge Controller for Wind Power Generation in Low Wind Speed Condition", "subitem_title_language": "en"}]}, "item_type_id": "3", "owner": "10", "path": ["55"], "permalink_uri": "https://fukuchiyama.repo.nii.ac.jp/records/333", "pubdate": {"attribute_name": "公開日", "attribute_value": "2017-07-03"}, "publish_date": "2017-07-03", "publish_status": "0", "recid": "333", "relation": {}, "relation_version_is_last": true, "title": ["低風速に対応する風力発電用蓄電装置の検討"], "weko_shared_id": -1}
低風速に対応する風力発電用蓄電装置の検討
https://fukuchiyama.repo.nii.ac.jp/records/333
https://fukuchiyama.repo.nii.ac.jp/records/3336f6175bf-1589-4510-b1c9-b52954e8ae74
名前 / ファイル | ライセンス | アクション |
---|---|---|
seibi42-5 (31.2 MB)
|
|
Item type | [ELS]紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-07-03 | |||||
タイトル | ||||||
タイトル | 低風速に対応する風力発電用蓄電装置の検討 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | The Review of the Charge Controller for Wind Power Generation in Low Wind Speed Condition | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 風力発電 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 蓄電 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | MPPT 回路 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 電気二重層コンデンサ | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | wind power generation | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | charge control | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Max Peak Power Tracking circuit | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | electric double -layer capacitor | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
雑誌書誌ID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AA12547156 | |||||
著者 |
神谷, 達夫
× 神谷, 達夫 |
|||||
抄録(日) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 本論文は、小規模風力発電における発電量向上のための回路方式を実験的に検討した。実験の結果、蓄電素子として電気二重層コンデンサ(EDLC)を用いることにより、従来から用いられている蓄電池を用いた回路に比べ、低風速で発電電力を蓄えることができた。また、MPPT(Max Peak Power Tracking)回路の付加により、同一発電条件での蓄電量を増加させることができた。 | |||||
書誌情報 |
成美大学紀要 巻 4, 号 2, p. 73-82, 発行日 2014-03-31 |
|||||
表示順 | ||||||
内容記述タイプ | Other | |||||
内容記述 | 5 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 21860300 |