{"created":"2023-05-15T09:31:16.590992+00:00","id":333,"links":{},"metadata":{"_buckets":{"deposit":"6679c54d-afa0-4cd6-a74b-d515682c3647"},"_deposit":{"created_by":10,"id":"333","owners":[10],"pid":{"revision_id":0,"type":"depid","value":"333"},"status":"published"},"_oai":{"id":"oai:fukuchiyama.repo.nii.ac.jp:00000333","sets":["1:33:54:55"]},"author_link":["444"],"item_3_biblio_info_12":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2014-03-31","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"82","bibliographicPageStart":"73","bibliographicVolumeNumber":"4","bibliographic_titles":[{"bibliographic_title":"成美大学紀要 "}]}]},"item_3_description_10":{"attribute_name":"抄録(日)","attribute_value_mlt":[{"subitem_description":"本論文は、小規模風力発電における発電量向上のための回路方式を実験的に検討した。実験の結果、蓄電素子として電気二重層コンデンサ(EDLC)を用いることにより、従来から用いられている蓄電池を用いた回路に比べ、低風速で発電電力を蓄えることができた。また、MPPT(Max Peak Power Tracking)回路の付加により、同一発電条件での蓄電量を増加させることができた。","subitem_description_type":"Other"}]},"item_3_description_15":{"attribute_name":"表示順","attribute_value_mlt":[{"subitem_description":"5","subitem_description_type":"Other"}]},"item_3_source_id_1":{"attribute_name":"雑誌書誌ID","attribute_value_mlt":[{"subitem_source_identifier":"AA12547156","subitem_source_identifier_type":"NCID"}]},"item_3_source_id_19":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"21860300","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"神谷, 達夫"},{"creatorName":"カミタニ, タツオ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"444","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-07-03"}],"displaytype":"detail","filename":"seibi42-5.pdf","filesize":[{"value":"31.2 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"seibi42-5","url":"https://fukuchiyama.repo.nii.ac.jp/record/333/files/seibi42-5.pdf"},"version_id":"48ea0772-0c52-4acb-908e-d8f79c4fa3ce"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"風力発電","subitem_subject_scheme":"Other"},{"subitem_subject":"蓄電","subitem_subject_scheme":"Other"},{"subitem_subject":"MPPT 回路","subitem_subject_scheme":"Other"},{"subitem_subject":"電気二重層コンデンサ","subitem_subject_scheme":"Other"},{"subitem_subject":"wind power generation","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"charge control","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Max Peak Power Tracking circuit","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"electric double -layer capacitor","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"低風速に対応する風力発電用蓄電装置の検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"低風速に対応する風力発電用蓄電装置の検討"},{"subitem_title":"The Review of the Charge Controller for Wind Power Generation in Low Wind Speed Condition","subitem_title_language":"en"}]},"item_type_id":"3","owner":"10","path":["55"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-07-03"},"publish_date":"2017-07-03","publish_status":"0","recid":"333","relation_version_is_last":true,"title":["低風速に対応する風力発電用蓄電装置の検討"],"weko_creator_id":"10","weko_shared_id":-1},"updated":"2023-05-15T09:39:47.492863+00:00"}